Blockwork rates
The rates here are base in UAE dirhams and as per my experience third fixing are very costly so you have to add additional ... and try not to include in your contracts the chasing becaused you wiil have to comeback to a certain level just to make the chasing due to electrical design layout were not ready so..give this to MEP contractors anyway they will be the one to insert the water line and electrical line..ok and note if the comback work were due for almost 2 months try to specify that you will will have a daywork charges because your tools and materials were already set up to a different level and you need to mobilize the tools and materials going back to the same area.
BASEMENT & PODIUM
WALLS AND PIERS
Concrete blockwork; as Specification 04200-2.1.1 (non fire rated construction); reinforced as drawing S0-M-05 m²
Walls; 150mm thick m² 95.00
Walls; 200mm thick m² 106.00
Walls; 200mm thick; curved m² 106.00
Concrete blockwork; as Specification 04200-2.1.2 (fire rated construction); reinforced as drawing S0-M-05
Walls; 150mm thick m² 114.00
Walls; 200mm thick m² 123.00
SUNDRIES
Expansion joints or the like m
25 wide joint to 150mm thick wall; insulation filler, sealant pointed both sides; as Drawing INT-405 m 28.00
25 wide joint to 150mm thick wall; insulation filler, sealant pointed both sides; as Drawing INT-405; 2 hour fire rated m 33.00
25 wide joint to 200mm thick wall; insulation filler, sealant pointed both sides; as Drawing INT-405 m 29.00
25 wide joint to 200mm thick wall; insulation filler, sealant pointed both sides; as Drawing INT-405; curved m 30.00
25 wide joint to 200mm thick wall; insulation filler, sealant pointed both sides; as Drawing INT-405; 2 hour fire rated m 35.00
Precast concrete lintel blocks, including in-situ infill concrete; as Specification 04200-3.4
Lintels; 150 x 190mm; 1Nr T12 bar m 115.00
Lintels; 200 x 190mm; 2Nr T12 bar m 115.00
Lintels; 200 x 190mm; 4Nr T16 bar m 115.00
100 x 100 x 150 long x 6mm thick (HEAD RESTRAIN) No 36.00
SLIDING TIES AT 800 MM C/C (ST-200) -
BASEMENT & PODIUM
WALLS AND PIERS
Concrete blockwork; as Specification 04200-2.1.1 (non fire rated construction); reinforced as drawing S0-M-05
Walls; 100mm thick m² 89.00
Walls; 100mm thick fire rated m² 107.00
Walls; 100mm thick curve 93.00
Concrete blockwork; as Specification 04200-2.1.2 (fire rated construction); reinforced as drawing S0-M-05
Walls; 250mm thick m² 139.00
Walls; 350mm thick m² 223.00
Walls; 300mm thick m² 204.00
SUNDRIES
Expansion joints or the like
25 wide joint to 100mm thick wall; insulation filler, sealant pointed both sides; as Drawing INT-405- 2 HOUR FIRE RATED m 32.00
25 wide joint to 100mm thick wall; insulation filler, sealant pointed both sides; as Drawing INT-405 m 26.00
25 wide joint to 250mm thick wall; insulation filler, sealant pointed both sides; as Drawing INT-405; 2 hour fire rated m 36.00
25 wide joint to 300mm thick wall; insulation filler, sealant pointed both sides; as Drawing INT-405; 2 hour fire rated m 36.00
25 wide joint to 350mm thick wall; insulation filler, sealant pointed both sides; as Drawing INT-405; 2 hour fire rated m 36.00
Precast concrete lintel blocks, including in-situ infill concrete; as Specification 04200-3.4
Lintels; 100 x 100mm; 2Nr T16 bar m 75.00
Lintels; 100 x 190mm; 4Nr T16 bar m 115.00
Lintels; 150 x 100mm; 2Nr T16 bar m 75.00
Lintels;150 x 190mm; 4Nr T16 bar m 115.00
Lintels; 200 x 100mm; 2Nr T16 bar m 98.00
TOWER A
WALLS AND PIERS
Concrete blockwork; as Specification 04200-2.1.1 (non fire rated construction); reinforced as drawing S0-M-05
Walls; 100mm thick m² 89.00
Walls; 200mm thick m² 106.00
Walls; 200mm thick; curved m² 106.00
Concrete blockwork; as Specification 04200-2.1.2 (fire rated construction); reinforced as drawing S0-M-05
Walls; 100mm thick m² 105.00
Walls; 150mm thick m² 114.00
Walls; 200mm thick m² 123.00
Walls; 250mm thick -
Walls; 300mm thick 194.00
SUNDRIES
Expansion joints or the like
25 wide joint to 100mm thick wall; insulation filler, sealant pointed both sides; as Drawing INT-405 m 26.00
25 wide joint to 100mm thick wall; insulation filler, sealant pointed both sides; as Drawing INT-405;2 hour fire rated m 32.00
25 wide joint to 150mm thick wall; insulation filler, sealant pointed both sides; as Drawing INT-405; 2 hour fire rated m 33.00
SUNDRIES (CONT'D)
Expansion joints or the like (Cont'd)
25 wide joint to 200mm thick wall; insulation filler, sealant pointed both sides; as Drawing INT-405 m 29.00
25 wide joint to 200mm thick wall; insulation filler, sealant pointed both sides; as Drawing INT-405; curved m 30.00
25 wide joint to 200mm thick wall; insulation filler, sealant pointed both sides; as Drawing INT-405: 2 hour fire rated m 35.00
25 wide joint to 250mm thick wall; insulation filler, sealant pointed both sides; as Drawing INT-405: 2 hour fire rated m -
25 wide joint to 300mm thick wall; insulation filler, sealant pointed both sides; as Drawing INT-405; 2 hour fire rated m 37.00
Precast concrete lintel blocks, including in-situ infill concrete; as Specification 04200-3.4
Lintels; 100 x 190mm; 1Nr T12 bar m
Lintels; 100 x 190mm; 1Nr T16 bar m
Lintels; 100 x 190mm; 2Nr T16 bar m
Lintels; 100 x 390mm; 1Nr T16 bar m
Lintels;150 x 190mm; 1Nr T12 bar m
Lintels; 150 x 190mm; 2Nr T12 bar m
Lintels; 150 x 190mm; 4Nr T16 bar m 105.00
Lintels; 200 x 190mm; 2Nr T12 bar m
Lintels; 200 x 190mm; 2Nr T16 bar m
Lintels; 200 x 190mm; 4Nr T16 bar m
Galvanised steel blockwork wall head restraint angles
100 x 100 x 150 long x 6mm thick No 36.00
SLIDING TIES AT 800 MM C/C (ST-200) No -
TOWER 'A'
WALLS AND PIERS
Concrete blockwork; as Specification 04200-2.1.1 (non fire rated construction); reinforced as drawing S0-M-05 m
Walls; 150mm thick m 96.00
Walls; 250mm thick m 122.00
Walls; 350mm thick m 179.00
Expansion joints or the like m
25 wide joint to 150mm thick wall; insulation filler, sealant pointed both sides; as Drawing INT-405 m 28.00
25 wide joint to 250mm thick wall; insulation filler, sealant pointed both sides; as Drawing INT-405 m 30.00
25 wide joint to 350mm thick wall; insulation filler, sealant pointed both sides; as Drawing INT-405 m 39.00
Precast concrete lintel blocks, including in-situ infill concrete; as Specification 04200-3.4
Lintels; 100 x 100mm; 2Nr T16 bar m 75.00
Lintels; 100 x 190mm; 4Nr T16 bar m 115.00
Lintels; 150 x 100mm; 2Nr T16 bar m 75.00
Lintels; 200 x 100mm; 2Nr T16 bar m 98.00
Lintels; 200 x 190mm; 4Nr T16 bar m 115.00
TOWER 'B'
WALLS AND PIERS
Concrete blockwork; as Specification 04200-2.1.1 (non fire rated construction); reinforced as drawing S0-M-05
Walls; 100mm thick m² 89.00
Walls; 100mm thick; curved m² -
Walls; 150mm thick m² 96.00
Walls; 200mm thick m² 106.00
Walls; 200mm thick; curved m² 109.00
Walls; 250mm thick m² 122.00
Walls; 300mm thick m² 135.00
Walls; 300mm thick; curved m² 179.00
Concrete blockwork; as Specification 04200-2.1.2 (fire rated construction); reinforced as drawing S0-M-05
Walls; 100mm thick m² 107.00
Walls; 150mm thick m² 114.00
Walls; 200mm thick m² 123.00
Walls; 400mm thick m² 223.00
SUNDRIES
Expansion joints or the like
25 wide joint to 100mm thick wall; insulation filler, sealant pointed both sides; as Drawing INT-405 m 26.00
25 wide joint to 100mm thick wall; insulation filler, sealant pointed both sides; as Drawing INT-405; curved m 28.00
25 wide joint to 100mm thick wall; insulation filler, sealant pointed both sides; as Drawing INT-405; 2 hour fire rated m 32.00
25 wide joint to 150mm thick wall; insulation filler, sealant pointed both sides; as Drawing INT-405 m 28.00
25 wide joint to 150mm thick wall; insulation filler, sealant pointed both sides; as Drawing INT-405; 2 hour fire rated m 33.00
25 wide joint to 200mm thick wall; insulation filler, sealant pointed both sides; as Drawing INT-405 m 29.00
25 wide joint to 200mm thick wall; insulation filler, sealant pointed both sides; as Drawing INT-405; curved m 30.00
25 wide joint to 200mm thick wall; insulation filler, sealant pointed both sides; as Drawing INT-405; 2 hour fire rated m 35.00
25 wide joint to 250mm thick wall; insulation filler, sealant pointed both sides; as Drawing INT-405 m 30.00
25 wide joint to 250mm thick wall; insulation filler, sealant pointed both sides; as Drawing INT-405; 2 hour fire rated m 32.00
25 wide joint to 400mm thick wall; insulation filler, sealant pointed both sides; as Drawing INT-405; 2 hour fire rated m 39.00
Precast concrete lintel blocks, including in-situ infill concrete; as Specification 04200-3.4
Lintels; 100 x 190mm; 1Nr T12 bar m
Lintels; 100 x 190mm; 1Nr T16 bar m
Lintels; 100 x 190mm; 2Nr T16 bar m
Lintels;150 x 190mm; 1Nr T12 bar m
Lintels; 150 x 190mm; 2Nr T12 bar m
Lintels; 150 x 190mm; 4Nr T16 bar m 105.00
Lintels; 200 x 190mm; 2Nr T12 bar m
Lintels; 200 x 190mm; 2Nr T16 bar m
Lintels; 200 x 190mm; 4Nr T16 bar m 115.00
Lintels; 250 x 190mm; 2Nr T12 bar m
Galvanised steel blockwork wall head restraint angles
100 x 100 x 150 long x 6mm thick No 36.00
SLIDING TIES AT 800 MM C/C (ST-200) -
TOWER 'B'
WALLS AND PIERS
Concrete blockwork; as Specification 04200-2.1.2 (fire rated construction); reinforced as drawing S0-M-05
Walls; 300mm thick m 204.00
Walls; 350mm thick m 223.00
Walls; 250mm thick m 139.00
Expansion joints or the like m
25 wide joint to 300mm thick wall; insulation filler, sealant pointed both sides; as Drawing INT-405; 2 hour fire rated m 37.00
26 wide joint to 350mm thick wall; insulation filler, sealant pointed both sides; as Drawing INT-405; 2 hour fire rated m 39.00
25 wide joint to 250mm thick wall; insulation filler, sealant pointed both sides; as Drawing INT-405; 2 hour fire rated m 30.00
Precast concrete lintel blocks, including in-situ infill concrete; as Specification 04200-3.4
Lintels; 100 x 100mm; 2Nr T16 bar m 75.00
Lintels; 100 x 190mm; 4Nr T16 bar m 115.00
Lintels; 150 x 100mm; 2Nr T16 bar m 75.00
Lintels; 150 x 190mm; 4Nr T16 bar m -
Lintels; 200 x 100mm; 2Nr T16 bar m 98.00
TOWER 'C'
WALLS AND PIERS
Concrete blockwork; as Specification 04200-2.1.1 (non fire rated construction); reinforced as drawing S0-M-05
Walls; 100mm thick m² 89.00
Walls; 200mm thick m² 106.00
Walls; 200mm thick; curved m² 109.00
Concrete blockwork; as Specification 04200-2.1.2 (fire rated construction); reinforced as drawing S0-M-05
Walls; 100mm thick m² 107.00
Walls; 150mm thick m² 114.00
Walls; 200mm thick m² 123.00
Walls; 250mm thick m² -
Walls; 300mm thick m² 204.00
SUNDRIES
Expansion joints or the like
25 wide joint to 100mm thick wall; insulation filler, sealant pointed both sides; as Drawing INT-405 m 26.00
25 wide joint to 100mm thick wall; insulation filler, sealant pointed both sides; as Drawing INT-405; 2 hour fire rated m 32.00
25 wide joint to 150mm thick wall; insulation filler, sealant pointed both sides; as Drawing INT-405; 2 hour fire rated m 33.00
SUNDRIES (CONT'D)
Expansion joints or the like (Cont'd)
25 wide joint to 200mm thick wall; insulation filler, sealant pointed both sides; as Drawing INT-405 m 29.00
25 wide joint to 200mm thick wall; insulation filler, sealant pointed both sides; as Drawing INT-405; curved m 30.00
25 wide joint to 200mm thick wall; insulation filler, sealant pointed both sides; as Drawing INT-405; 2 hour fire rated m 35.00
25 wide joint to 250mm thick wall; insulation filler, sealant pointed both sides; as Drawing INT-405; 2 hour fire rated m 36.00
25 wide joint to 300mm thick wall; insulation filler, sealant pointed both sides; as Drawing INT-405; 2 hour fire rated m 37.00
Precast concrete lintel blocks, including in-situ infill concrete; as Specification 04200-3.4
Lintels; 100 x 190mm; 1Nr T12 bar m
Lintels; 100 x 190mm; 1Nr T16 bar m
Lintels; 100 x 190mm; 2Nr T16 bar m
Lintels;100 x 390mm; 1Nr T16 bar m
Lintels; 150 x 190mm; 1Nr T12 bar m
Lintels; 150 x 190mm; 2Nr T12 bar m
Lintels; 150 x 190mm; 4Nr T16 bar m 105.00
Lintels; 200 x 190mm; 2Nr T12 bar m
Lintels; 200 x 190mm; 2Nr T16 bar m
Lintels; 200 x 190mm; 4Nr T16 bar m 115.00
Lintels; 300 x 190mm; 2Nr T16 bar m
Galvanised steel blockwork wall head restraint angles
100 x 100 x 150 long x 6mm thick No 36.00
SLIDING TIES AT 800 MM C/C (ST-200) -
TOWER 'C'
Concrete blockwork; as Specification 04200-2.1.1 (non fire rated construction); reinforced as drawing S0-M-05 No
Walls; 150mm thick m² 96.00
Walls; 250mm thick m² 122.00
Walls; 350mm thick m² 179.00
Expansion joints or the like
25 wide joint to 150mm thick wall; insulation filler, sealant pointed both sides; as Drawing INT-405 m 28.00
25 wide joint to 250mm thick wall; insulation filler, sealant pointed both sides; as Drawing INT-405 m 32.00
28 wide joint to 350mm thick wall; insulation filler, sealant pointed both sides; as Drawing INT-405 m 39.00
25 wide joint to 300mm thick wall; insulation filler, sealant pointed both sides; as Drawing INT-405 m -
Precast concrete lintel blocks, including in-situ infill concrete; as Specification 04200-3.4
Lintels; 100 x 100mm; 2Nr T16 bar m 75.00
Lintels; 100 x 190mm; 4Nr T16 bar m 115.00
Lintels; 150 x 100mm; 2Nr T16 bar m 75.00
WALLS AND PIERS-PODIUM APARTMENTS
WALLS AND PIERS
Concrete blockwork; as Specification 04200-2.1.1 (non fire rated construction); reinforced as drawing S0-M-05
Walls; 100mm thick m² 89.00
Walls; 150mm thick m² 96.00
Walls; 200mm thick m² 106.00
Walls; 250mm thick m² 122.00
Walls; 300mm thick m² 135.00
Concrete blockwork; as Specification 04200-2.1.2 (fire rated construction); reinforced as drawing S0-M-05
Walls; 150mm thick m² 114.00
Walls; 200mm thick m² 123.00
Cavity walls; comprising 200 thick outer skin, 200 inner skin; 100mm wide cavity m²
SUNDRIES
Expansion joints or the like
25 wide joint to 100mm thick wall; insulation filler, sealant pointed both sides; as Drawing INT-405 m 26.00
25 wide joint to 150mm thick wall; insulation filler, sealant pointed both sides; as Drawing INT-405 m 28.00
25 wide joint to 150mm thick wall; insulation filler, sealant pointed both sides; as Drawing INT-405; 2 hour fire rated m 33.00
SUNDRIES (CONT'D)
Expansion joints or the like (Cont'd)
25 wide joint to 200mm thick wall; insulation filler, sealant pointed both sides; as Drawing INT-405 m 29.00
25 wide joint to 200mm thick wall; insulation filler, sealant pointed both sides; as Drawing INT-405; 2 hour fire rated m 35.00
25 wide joint to 250mm thick wall; insulation filler, sealant pointed both sides; as Drawing INT-405 m 30.00
25 wide joint to 300mm thick wall; insulation filler, sealant pointed both sides; as Drawing INT-405 m 32.00
25 wide joint to 500mm thick wall; insulation filler, sealant pointed both sides; as Drawing INT-405; 2 hour fire rated m 42.00
Precast concrete lintel blocks, including in-situ infill concrete; as Specification 04200-3.4
Lintels; 100 x 190mm; 1Nr T12 bar m
Lintels; 150 x 190mm; 1Nr T12 bar m
Lintels;150 x 190mm; 4Nr T16 bar m 105.00
Lintels; 200 x 190mm; 2Nr T12 bar m
Lintels; 200 x 190mm; 4Nr T12 bar m
Lintels; 250 x 190mm; 2Nr T12 bar m
Lintels; 300 x 190mm; 3Nr T12 bar m
Galvanised steel blockwork wall head restraint angles
100 x 100 x 150 long x 6mm thick No 36.00
SLIDING TIES AT 800 MM C/C (ST-200) -
PODIUM APARTMENTS
Concrete blockwork; as Specification 04200-2.1.2 (fire rated construction); reinforced as drawing S0-M-05
Walls; 100mm thick fire rated m² 107.00
Walls; 250mm thick m² 139.00
Walls; 300mm thick m² 204.00
Walls; 350mm thick m² 223.00
Concrete blockwork; as Specification 04200-2.1.2 (non fire rated construction); reinforced as drawing S0-M-04
Walls; 350mm thick m² 179.00
SUNDRIES
Expansion joints or the like
25 wide joint to 100mm thick wall; insulation filler, sealant pointed both sides; as Drawing INT-405; 2 hour fire rated m 32.00
26 wide joint to 250mm thick wall; insulation filler, sealant pointed both sides; as Drawing INT-405; 2 hour fire rated m 36.00
26 wide joint to 300mm thick wall; insulation filler, sealant pointed both sides; as Drawing INT-405; 2 hour fire rated m 37.00
25 wide joint to 350mm thick wall; insulation filler, sealant pointed both sides; as Drawing INT-405; 2 2 hour fire rated m 39.00
25 wide joint to 350mm thick wall; insulation filler, sealant pointed both sides; as Drawing INT-405; m 39.00
Precast concrete lintel blocks, including in-situ infill concrete; as Specification 04200-3.4
Lintels; 100 x 100mm; 2Nr T16 bar m 75.00
Lintels; 100 x 190mm; 4Nr T16 bar m 115.00
Lintels; 150 x 100mm; 2Nr T16 bar m 75.00
Lintels; 200 x 100mm; 2Nr T16 bar m 98.00
Lintels; 200 x 190mm; 4Nr T16 bar m 115.00
Lintels; 250 x 100mm; 2Nr T16 bar m 115.00
Extra Over for Fair Faced Blockwork m² 32.00
Extra Over for Fair Faced Blockwork inside the mechanical shaft as per AFC Project Manager instruction m2 32.00
ADDITIONAL FAIRFACE WORKS IN MAY m2 32.00
Extra Over for Pointing Works m² 22.00
Vertical Control Joints m 24.00
200MM THERMAL BLOCK WORK TOWER B m² 386.00
Labels: Blockworks, Civil engineering, Quantity Surveying, Rates